AX UPS

AX UPS
Reliable, true online double-conversion UPS design with built-in internal battery, ideal for protecting critical loads that require continuous, high-quality AC power with zero transfer time to battery such as servers.
True online double conversion design
Fully digitized microprocessor control
Input Power Factor Correction (PFC)
Wide input voltage range
on-line output voltage selection
Auto self-testing system while turning on the UPS
Eco mode for energy saving
Generator compatible
Built in Automatic bypass
Advanced Battery Management (ABM Technology)
Automatic diagnostics and battery check
Audible alarm & LED power status Display
Smart RS-232 or USB communication port
Software monitoring and control

Specifications

Model AX-1200
Input
Rating
Voltage
Voltage range
Frequency
Power Factor
1200VA
220/230/240 VAC, 1Ø2Wires
160~280VAC+/-5%
50 or 60 Hz +/-10% (auto sensing)
>95%
Ouput
Output Power with cosφ=0.8
Voltage (backup mode)
Frequency (backup mode)
Transfer Time
UPS Design Technology
Output Wave Form
700W
220/230/240 VAC +/-1%, 1Ø2Wires
50 or 60 Hz +/-1%
0 ms
On-Line / Fully digitized microprocessor controlled
Pure Sinewave
Protection
Full Protection
Overload, discharge/overcharge and short circuit protection
System Display
LED indicators
Load level, Battery level, AC mode, Battery mode, Bypass mode and Fault indicators
Audible Alarm
Battery mode
Low battery
Overload
Bypass Mode
Sounding every 4 seconds
Sounding every second
Sounding twice every second
Sounding every 10 seconds
Battery
Battery Type & Number
DC Voltage
Typical Recharge Time
Charging Current
Backup time
SLA 12V/7AH x 2
24VDC
4-6 hours (to 90% full capacity)
1A
10~20min depending on load level
Communication
Fault
USB or RS232
Compatibility
Output Receptacles
Continuously sounding
Interface with power management software
Windows 2000/XP/2003/2008/Vista/7, LINUX, UNIX, MAC
Universal sockets x 2
Physical
Dimension WxDxH mm (inch)
Net Weight kg (lbs)
145x282x220
9.8
Environment
Ambient operation
Audible noise
Maximum elevation at 3500m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
< 45 dBA (1 meter from surface)
Standards & Certifications
Safety
Electromagnetic compatibility
Design, production, & services
Environment
Marking & Certifications
EN 50091-1-1/EN 69050 (RD), IEC 60950, TUV GC-Mark
EN 50091-2, EN 50022/B, IEC 62040-2, IEC 61000-3-2, IEC 61000-3-3
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*Product specifications are subject to change without further notice

** UPS will transfer to Eco mode when long-time running on online mode with load higher than 60%

related products

  • MXL 1~10k

    MXL 1~10k

    Long autonomy UPS True on-line double...more
  • MXRM 1~10k

    MXRM 1~10k

    double-conversion online UPS Wide...more
  • MXLRM 1~10k

    MXLRM 1~10k

    True double-conversion online UPS Wide...more
  • VX 1~10k

    VX 1~10k

    True on-line double conversion...more
  • VXL 1~10k

    VXL 1~10k

    Long autonomy UPS True on-line double...more
  • MX 1~10k

    MX 1~10k

    True on-line double conversion...more
  • MX 10~20k 31

    MX 10~20k 31

    True on-line double conversion...more
  • MXRM 10~20k 31

    MXRM 10~20k 31

    True double-conversion DSP technology...more
  • X9 1~10k

    X9 1~10k

    True online double conversion UPS...more
  • X9L 1~10k

    X9L 1~10k

    True online double conversion, long...more
  • MXL 10~20k 31

    MXL 10~20k 31

    Long autonomy UPS True online double...more
  • MXLRM 10~20k 31

    MXLRM 10~20k 31

    Long autonomy UPS True online double...more