With its true online double conversion design, DSP technology, and active input power factor correction, the MX Series provides the highest quality power protection solution for critical system installation such as servers, networks and workstations. Redundancy and load-sharing are possible for 6/10kVA models.
True online double conversion design
Fully digitized microprocessor control
Digital Signal Processor technology (DSP)
N+1 parallel redundancy configuration*
Up to 4 units connected in parallel*
Input Power Factor Correction (PFC)
Pure sinewave output with less than 3% THD
Wide input voltage range
Eco mode for energy saving
Frequency converter mode
*Select models only
Cold start function (DC power on)
Optional Galvanic isolation transformer
Generator compatible
Built in Automatic bypass
Programmable power management outlets
Remote Emergency Power Off function (EPO)
Advanced Battery Management (ABM Technology)
Multi-function LCD display
RS-232/USB/ Optional SNMP & AS-400 communication port
Software monitoring and control

Specifications

Model MX 1k
Input
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
1000VA
220V, 230V, 240V, 1Ø 2Wires
40Hz~70Hz
160-300 VAC @ 100% load, 110-300 VAC @ 50% load
>99%
<4%
Ouput
Output Power with cosφ=0.8
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
900W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.1Hz
0 ms
On-Line / Fully digitized microprocessor controlled
Pure Sinewave
<2% of T.H.D. at linear load, <4% T.H.D. at non linear load
3:1
Efficiency
AC Mode
Battery Mode
90%
89%
Protection
Overload Protection
Short Circuit Protection
125% for 10 minutes and 150% for 1 minute or 110% for 10min, 110~130% for 1 min,>130% for 1 sec
UPS output cut off immediately using input fuse/circuit breaker protection
System Display
LED indicators
LCD indicators
Sixteen LEDs indicating UPS status, Load level, Battery level, overload, fault, and programmable outlet information
UPS Status, Load level, Battery level, Input/Output voltage, Discharge time, and Fault indicators
Alarm
Battery mode
Low battery
Overload
Fault
Beep every 4 second
Beep every second
Beep twice every second
Continuously beeping
Battery
Battery Type
Typical Recharge Time
Charging Current
DC Voltage
Back up time(1/2 Load)
Sealed, maintenance-free lead acid batteries, 3-5 years typical life time
4 hours to 90% capacity
1.5A
36 VDC
22 min
Communication
USB, RS-232, AS-400**
SNMP**
Compatibiltiy
Interface with power management software
Power Management from SNMP manager and web browser
Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-U X and MAC/ME
Physical
Dimension, WxDxH mm
Net Weight kgs(lbs)
145 X 397 X 220
13 (28.6lbs)
Environment
Ambient operation
Audible noise
Maximum elevation at 3500m, 0 to 40°C, 0 to 95% humidity (non-condensing)
<50dBA at 1 Meter
Standards & Certifications
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
* NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice

related products

  • MXL 1~10k

    MXL 1~10k

    Long autonomy UPS True on-line double...more
  • MXRM 1~10k

    MXRM 1~10k

    double-conversion online UPS Wide...more
  • MXLRM 1~10k

    MXLRM 1~10k

    True double-conversion online UPS Wide...more
  • VX 1~10k

    VX 1~10k

    True on-line double conversion...more
  • VXL 1~10k

    VXL 1~10k

    Long autonomy UPS True on-line double...more
  • MX 10~20k 31

    MX 10~20k 31

    True on-line double conversion...more
  • MXRM 10~20k 31

    MXRM 10~20k 31

    True double-conversion DSP technology...more
  • X9 1~10k

    X9 1~10k

    True online double conversion UPS...more
  • X9L 1~10k

    X9L 1~10k

    True online double conversion, long...more
  • AX UPS

    AX UPS

    True online double conversion design...more
  • MXL 10~20k 31

    MXL 10~20k 31

    Long autonomy UPS True online double...more
  • MXLRM 10~20k 31

    MXLRM 10~20k 31

    Long autonomy UPS True online double...more