MXL 10~20k 31

MXL 10~20k 31
The MXL series adopts true online double conversion design, DSP technology and high 0.99 PFC to deliver the optimum level of reliability, purity and power protection for critical system installation such as data centers and communication systems. The long autonomy UPS can be optionally configured to parallel redundancy which increases flexibility and reliability.
Long autonomy UPS
True online double conversion design
Fully digitized microprocessor control
Digital Signal Processor technology (DSP)
N+1 parallel redundancy configuration*
Up to 4 units connected in parallel*
Input Power Factor Correction (PFC)
Pure sinewave output with less than 2% THD
Wide input voltage range
Eco mode for energy saving
Frequency converter mode
Cold start function (DC power on)
*Optional
Galvanic isolation transformer*
Generator compatible
Automatic and manual bypass setting
Remote Emergency Power Off function (EPO)
Advanced Battery Management (ABM Technology)
Display of battery remaining time
extended back up times by adding extra battery packs
Adjustable battery number
Adjustable charging current via LCD or software
Multi-function LCD display
RS-232/USB/ Optional SNMP/AS-400/dry contact communication port
Software monitoring and control

Specifications

Model MXL 10K 31
Input
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
10000VA
380V, 400V, 415V (selectable), 3Φ4Wires
50/60 Hz +/-10%
305-478 VAC @ 100% load 190-520 VAC @ 50% load
>99%
<3%
Ouput
Output Power with cosφ=0.8
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
9000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø2Wires
50/60 Hz +/-0.2%
0 ms
On-Line / Fully digitized microprocessor controlled
Pure Sinewave
<2% of T.H.D. at linear load, <5% T.H.D. at non linear load
3:1
Efficiency
AC Mode
Battery Mode
92%
89%
Protection
Overload Protection
Short Circuit Protection
125% for 10 minutes and 150% for 1 minute or 110% for 10min, 110~130% for 1 min,>130% for 1 sec
UPS output cut off immediately using input fuse/circuit breaker protection
System Display
LED indicators
LCD indicators
On-line mode, back up mode, CVCF mode, Eco mode, batt. test, fault status
UPS Status, Load level, Battery level, Input/Output voltage, Discharge time, and Fault indicators
Alarm
Battery mode
Low battery
Overload
Fault
Beep every 4 second
Beep every second
Beep twice every second
Continously sounding
Battery
Battery Type
Typical Recharge Time
Charging Current
Battery number
Extended Back up time
Depending on applications
Depending on capacity of external batteries
4A
Depending on capacity of external batteries
Longer backup time depending on extra battery pack
Communication
USB, RS-232, AS-400**
SNMP**
Compatibiltiy
Interface with power management software
Power Management from SNMP manager and web browser
Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-U X and MAC/ME
Physical
W x D x H mm
Net Weight kgs
250 X 592 x 576
28
Environment
Ambient operation
Audible noise
Maximum elevation at 3500m, 0 to 40ºC, 0 to 95% humidity (non-condensing)
<50dBA at 1 Meter
Standards & Certifications
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further notice

related products

  • MXL 1~10k

    MXL 1~10k

    Long autonomy UPS True on-line double...more
  • MXRM 1~10k

    MXRM 1~10k

    double-conversion online UPS Wide...more
  • MXLRM 1~10k

    MXLRM 1~10k

    True double-conversion online UPS Wide...more
  • VX 1~10k

    VX 1~10k

    True on-line double conversion...more
  • VXL 1~10k

    VXL 1~10k

    Long autonomy UPS True on-line double...more
  • MX 1~10k

    MX 1~10k

    True on-line double conversion...more
  • MX 10~20k 31

    MX 10~20k 31

    True on-line double conversion...more
  • MXRM 10~20k 31

    MXRM 10~20k 31

    True double-conversion DSP technology...more
  • X9 1~10k

    X9 1~10k

    True online double conversion UPS...more
  • X9L 1~10k

    X9L 1~10k

    True online double conversion, long...more
  • AX UPS

    AX UPS

    True online double conversion design...more
  • MXLRM 10~20k 31

    MXLRM 10~20k 31

    Long autonomy UPS True online double...more