MXRM 10~20k 31

MXRM 10~20k 31
With its true online double conversion design, DSP technology, and active input power factor correction, the MX RM Series provides the highest quality power protection solution for critical system installation such as data centers and communication systems. The rack-tower UPS can be optionally configured to parallel redundancy which increases flexibility and reliability.
True online double conversion design
Fully digitized microprocessor control
Digital Signal Processor technology (DSP)
Rack-Tower 2 in 1 design
N+1 parallel redundancy configuration*
Up to 4 units connected in parallel*
Input Power Factor Correction (PFC)
Pure sinewave output with less than 2% THD
Wide input voltage range
Eco mode for energy saving
Frequency converter mode
**Optional
Cold start function (DC power on)
Galvanic isolation transformer*
Generator compatible
Automatic and Manual bypass setting
Remote Emergency Power Off function (EPO)
Advanced Battery Management (ABM Technology)
Adjustable battery number
Adjustable charging current via LCD or software
Multi-function LCD display
RS-232/USB/ Optional SNMP/AS-400/dry contact communication port
Software monitoring and control

Specifications

Model MX RM 10K 31
Input
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
10000VA
380V, 400V, 415V (selectable) , 3Φ4wires
50/60 Hz +/-10%
305-478 VAC @ 100% load; 190-520 @ 50% load
>99%
<3%
Ouput
Active Power @ PF=0.8
Voltage (on battery)
Frequency (on battery)
Transfer Time
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
8000W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.2%
0 ms
On-Line / Fully digitized microprocessor controlled
Pure Sinewave
< 2% of T.H.D. at linear load , < 5% T.H.D. at non linear load
3:1
Efficiency
AC Mode
Battery Mode
94%
89%
Protection
Overload Protection
Short Circuit Protection
125% for 10 minutes and 150% for 1 minute or 110% for 10min,110~130% for 1 min,>130% for 1 sec
UPS output cut off immediately using input fuse/circuit breaker protection
System Display
LED indicators
LCD indicators
On-line mode, back up mode, CVCF mode, Eco mode, batt. test, fault status
UPS Status, Load level, Battery level, Input/Output voltage, Discharge time, and Fault indicators
Alarm
Battery Mode
Low Battery
Overload
Fault
Sounding every 4 seconds
Sounding every second
Beep twice every second
Continously sounding
Battery
Battery Type
Typical Recharge Time
Charging Current
Battery number
Back up time(1/2 Load)
Sealed, maintenance-free lead acid batteries, 3-5 years typical life time
5 hours to 90% capacity
1A
20 pcs (18 - 20 pcs adjustable)*
18 min
Communication
USB, RS-232, AS-400**
SNMP**
Compatibiltiy
Interface with power management software
Power Management from SNMP manager and web browser
Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-U X and MAC/ME
Physical
W x D x H mm
Net Weight kgs(lbs)
UPS: 438 X 668 x 133[3U] Battery Pack:438 x 580 x 133[3U]
UPS: 22(48.4lbs) Battery: 63(138.6lbs)
Environment
Ambient operation
Audible noise
Maximum elevation at 3500m, 0 to 40°C, 0 to 95% humidity (non-condensing)
<50dBA at 1 Meter
Standards & Certifications
Performance
Safety
EMC (EMS / EMI)
Design, production, and services
Environment
Marking & Certificationsment
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950

IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22,
EN 50091-2/IEC62040-2 Class A EN 55022/B,FCC 47 part 15 - Subpart B -

ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
*When using internal batteries from 18-19, the unit will de-rate according to below formula: P=Prating x N/20
NOTE 1: Derate to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than the rated altitude, the output power must be derated one percent per 100m.
** For optional features
***Product specifications are subject to change without further noticee

related products

  • MXL 1~10k

    MXL 1~10k

    Long autonomy UPS True on-line double...more
  • MXRM 1~10k

    MXRM 1~10k

    double-conversion online UPS Wide...more
  • MXLRM 1~10k

    MXLRM 1~10k

    True double-conversion online UPS Wide...more
  • VX 1~10k

    VX 1~10k

    True on-line double conversion...more
  • VXL 1~10k

    VXL 1~10k

    Long autonomy UPS True on-line double...more
  • MX 1~10k

    MX 1~10k

    True on-line double conversion...more
  • MX 10~20k 31

    MX 10~20k 31

    True on-line double conversion...more
  • X9 1~10k

    X9 1~10k

    True online double conversion UPS...more
  • X9L 1~10k

    X9L 1~10k

    True online double conversion, long...more
  • AX UPS

    AX UPS

    True online double conversion design...more
  • MXL 10~20k 31

    MXL 10~20k 31

    Long autonomy UPS True online double...more
  • MXLRM 10~20k 31

    MXLRM 10~20k 31

    Long autonomy UPS True online double...more