VXL 1~10k

VXL 1~10k
True online double conversion, long autonomy UPS design equipped with DSP technology for increased power efficiency and power density. VXL Series gives the highest operating reliability for the most mission-critical applications such as servers, networks and workstations.Highly flexible UPS offering the possibility to easily adjust battery numbers for diverse applications and the charging current for higher back up times.
Long autonomy UPS
True online double conversion design
Fully digitized microprocessor control
Digital Signal Processor technology (DSP)
Input Power Factor Correction (PFC)
Pure sinewave output with less than 3% THD
Wide input voltage range
Eco mode for energy saving
Frequency converter mode
Cold start function (DC power on)
* Select models only
Built in Automatic bypass
Manual bypass setting*
Remote Emergency Power Off function (EPO)
Advanced Battery Management (ABM Technology)
Extended Back up time by adding extra battery packs
Adjustable battery number*
Adjustable charging current via LCD or software*
Multi-function LCD display
USB, RS-232, Optional SNMP slot communication port
Software monitoring and control

Specifications

Model VXL 1K
Input
Rating
Voltage
Frequency
Voltage range
Power Factor
THDi
1000VA
220V, 230V, 240V, 1Ø 2Wires
40~70Hz
110V~300VAC
>99%
<5%
Ouput
Active Power @ PF=0.8
Voltage (on battery)
Frequency (on battery)
Transfer Time
Efficiency
UPS Design Technology
Output Wave Form
Total Harmonic distortion (THD)
Crest Factor
800W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.2%
0 ms
>94%
On-Line / Fully digitized microprocessor controlled
Pure Sinewave
< 3% of T.H.D. at linear load , < 5% T.H.D. at non linear load
3:1
Protection
Overload Protection
Short Circuit Protection
125% for 10 minutes and 150% for 1 minute or 110% for 10min,110~130% for 1 min,>130% for 1 sec
UPS output cut off immediately using input fuse/circuit breaker protection
System Display
LCD indicators
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
Alarm
Battery mode
Low battery
Overload
Fault
Beep every 4 second
Beep every second
Beep twice every second
Continuously beeping
Battery
Battery Type
Typical Recharge Time
DC Voltage
Charging Current
Extended Back up time
Sealed, maintenance-free lead acid batteries, 3-5 years typical life time
Depending on external batteries
24VDC or 36VDC
1A/2A/4A/6A
Longer backup time depending on extra battery pack
Communication
USB or RS-232
SNMP*
Compatibiltiy
Interface with power management software
Power Management from SNMP manager and web browser
Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64,SGI IRIX, FreeBSD, HP-U X and MAC/ME
Physical
W x D x H mm
Net Weight kgs(lbs)
145x282x220mm
4.1Kg(9lbs)
Environment
Operating Temperature
Storage Temperature
Altitude
Audible noise
Relative Humidity
0 - 40 °C / 32 ~ 104°F
-20 ~ 50°C / -4 ~ 122°F
1,500 meters max
<50dBA at 1 Meter
0 ~ 95% humidity, non-condensing
Standards & Certifications
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3,FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2 Class A, EN 55022/B,FCC 47 part 15 - Subpart B -
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
* For optional features
***Product specifications are subject to change without further notice

related products

  • MXL 1~10k

    MXL 1~10k

    Long autonomy UPS True on-line double...more
  • MXRM 1~10k

    MXRM 1~10k

    double-conversion online UPS Wide...more
  • MXLRM 1~10k

    MXLRM 1~10k

    True double-conversion online UPS Wide...more
  • VX 1~10k

    VX 1~10k

    True on-line double conversion...more
  • MX 1~10k

    MX 1~10k

    True on-line double conversion...more
  • MX 10~20k 31

    MX 10~20k 31

    True on-line double conversion...more
  • MXRM 10~20k 31

    MXRM 10~20k 31

    True double-conversion DSP technology...more
  • X9 1~10k

    X9 1~10k

    True online double conversion UPS...more