X9L 1~10k

X9L 1~10k
High output power factor 0.9, compact rack-tower, true online double conversion, long autonomy UPS design ideal for networks, servers and medium-density power protection applications requiring high availability. X9L UPS is a world class, redundant, scalable, high efficient power protection solution integrating the latest technology for high performance while maintaining small footprint.
Long autonomy UPS
True online double conversion design
Fully digitized microprocessor control
Digital Signal Processor technology (DSP)
Rack-Tower 2 in 1 design
N+1 parallel redundancy configuration*
Up to three units connected in parallel*
Input Power Factor Correction (PFC)
High output power factor 0.9
Pure sinewave output with less than 2% THD
Eco mode for energy saving
Frequency converter mode
* Select models only
Cold start function (DC power on)
Generator compatible
Manual & Automatic bypass
Programmable power management outlets
Remote Emergency Power Off function (EPO)
Advanced Battery Management (ABM Technology)
Hot swappable battery design*
Extended backup time by adding extra battery packs
Adjustable charging current via LCD or software
Multi-function LCD display
Smart RS-232/USB/ Optional SNMP & AS-400 communication port
Software monitoring and control

Specifications

Model X9L 1k
Input
Rating
Voltage
Voltage range
Power Factor
Frequency
1000VA
220V, 230V, 240V, 1Ø 2Wires
110VAC~300VAC depending on load level
>99%
40~70Hz
Ouput
Output Power with cosφ=0.9
Voltage (on battery)
Frequency (on battery)
Transfer Time
Overload Recovery
High Efficiency of inverter
UPS Design Technology
Output Wave Form
Harmonic distortion
Crest Factor
900W
220V, 230V, 240V, +/-1% (selectable output voltage), 1Ø 2Wires
50/60 Hz +/-0.5%
0 ms
Auto transfer to UPS
> 95%
On-Line / Fully digitized microprocessor controlled
Sine wave
< 2% of T.H.D. at linear load;<4% THD at non linear load
3:1
Protection
Surge Protection
Overload Protection
Short Circuit Protection
230V (IEEE C61000-4-5 level 3)
≤ 110% continuous, 110%~120% 30min., 120% ~ 130% 10 min., ≥130% 1 min
UPS outputs cut off immediately using input fuse/circuit breaker protection
System Display
LCD Indicator
Input/output voltage, input/output frequency, UPS status, load level, battery level,
battery capacity, discharge time, and fault indicators
Alarm
Battery Mode
Low Battery
Overload
Fault
Beep every 4 sec
Beep every sec
Beep twice every sec
Continuous beeping sound and LCD display
Battery
Type
DC Voltage
Cold Start (DC start)
Charging Current (max)
Back Up Time
Sealed, maintenance-free lead acid batteries, 3-5 years typical life time
24V
YES
1A/2A/4A/8A
Longer backup time depending on extra battery pack
Communication
USB, RS232, AS400*
SNMP*
Compatibility
Interface with power management software
Power management from SNMP manager and web browser
Supports Windows® 2000/2003/XP/Vista/2008, Windows®7, Linux, Unix, and MAC
Physical
Dimensions WxDxH mm
Net Weight kg (lb)
438x380x88 [2U]
8.6 (18.9)
Environment
Operating Temperature
Storage Temperature
Altitude
Audible Noise
Relative Humidity
0 - 40°C / 32 ~ 104 °F
-20 ~ 50°C / -4 ~ 122 °F
1,500 meters max
< 50 dBA @ 1 meter
0 ~ 95% humidity, non-condensing
Standards & Certifications
Performance
Safety
EMC (EMS / EMI)
Design, production, & services
Environment
Marking & Certifications
EN50091-3/IEC 62040-3
UL 1778, CE, EN 50091-1,EN 60950 (RD/), IEC 60950
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3, FCC Part 15, CISPR 22, EN 50091-2/IEC62040-2,EN 55022/B,FCC 47 part 15 - Subpart B - Class A
ISO 9001
ISO 14001 certified company
CE, TUV/GS, UL, cUL, c-Tick
 
*For optional features
****Specifications may change without further notice

related products

  • MXL 1~10k

    MXL 1~10k

    Long autonomy UPS True on-line double...more
  • MXRM 1~10k

    MXRM 1~10k

    double-conversion online UPS Wide...more
  • MXLRM 1~10k

    MXLRM 1~10k

    True double-conversion online UPS Wide...more
  • VX 1~10k

    VX 1~10k

    True on-line double conversion...more
  • VXL 1~10k

    VXL 1~10k

    Long autonomy UPS True on-line double...more
  • MX 1~10k

    MX 1~10k

    True on-line double conversion...more
  • MX 10~20k 31

    MX 10~20k 31

    True on-line double conversion...more
  • MXRM 10~20k 31

    MXRM 10~20k 31

    True double-conversion DSP technology...more
  • X9 1~10k

    X9 1~10k

    True online double conversion UPS...more
  • AX UPS

    AX UPS

    True online double conversion design...more
  • MXL 10~20k 31

    MXL 10~20k 31

    Long autonomy UPS True online double...more
  • MXLRM 10~20k 31

    MXLRM 10~20k 31

    Long autonomy UPS True online double...more